TOWER
MODEL |
SD
1103 |
SD1105 |
SD1106 |
SD1107 |
SD1110 |
19"
RACK MOUNT MODEL |
RMSD
1103 |
RMSD
1105 |
RMSD
1106 |
|
|
Power(kVA) |
3 |
5 |
6 |
7,5 |
10 |
INPUT |
| ||||
Nominal
Voltage |
220
V / 230 V | ||||
Minumum
Voltage |
80
V | ||||
Minumum
Voltage (at full load) |
160V | ||||
Maximum
Voltage |
280
V | ||||
Frequency |
45
- 65 Hz. | ||||
Power
Factor |
>0.99 | ||||
Input
Current Harmonics |
<
6 % | ||||
OUTPUT |
| ||||
Power
Factor |
0.7 | ||||
Nominal
Voltage |
220
V / 230 V (adjustable) | ||||
Nominal
Current |
13,6
A |
23
A |
27
A |
34
A |
45,5A |
Wave
Form |
Pure
Sine Wave | ||||
Total
Harmonic Distortion |
| ||||
At
100% Linear Load |
<
2,5 % | ||||
At
100% Non - Linear Load |
<
3,6 % | ||||
Frequency |
50
or 60 Hz. (adjustable) | ||||
Frequency
Tolerance (line-synchronized) |
0,005
% | ||||
Static
Voltage Regulation(0-100% Load) |
<
1 % | ||||
Crest
Factor |
3 | ||||
Overload(On
Mains)(150% Overload) |
63
Sec |
35
Sec |
49
Sec | ||
Overload(On
Battery)(150% Overload) |
63
Sec |
35
Sec |
49
Sec | ||
Total
Efficiency |
>
91,5 % | ||||
Greenmode
Efficiency |
>
97 % | ||||
BATTERY |
| ||||
Type |
Maintenance-free
lead acid batteries | ||||
Quantity
(pcs) |
14 |
20 | |||
Back
Up Time (At Nominal Load) |
Internal
up to 25 min at tower model |
Internal
up to 22 min at tower model |
Internal
up to 15 min at tower model |
Internal
up to 10 min at tower model |
Internal
up to 9 min at tower model |
Recharging
Time |
<
4h / 8 h | ||||
Discharge
Current Wave |
<
10% | ||||
DISPLAY |
| ||||
LED
Panel |
Line,
Bypass, Battery, Inverter, Overload, Fault
Indicators | ||||
LCD
Panel |
Load%,
Battery Temperature, Input&Output&Battery Voltages, Output
Frequency | ||||
STATIC
BY-PASS |
| ||||
Voltage
Tolerance |
10
% (adjustable) | ||||
Freguency
Tolerance |
3
Hz.(adjustable) | ||||
Transfer
Time |
0ms | ||||
PROTECTION |
| ||||
Overload
Protection |
Bypass
transfer time is calculated by simulating a temperature related model of a
fuse | ||||
Short
Circuit Protection |
Acts
as the ideal current source during the short circuit
time | ||||
Other
Protection |
Against
excessive (heat, voltage, current) intense battery
discharge | ||||
COMMUNICATION |
| ||||
Interface
(Communication Ports) |
RS232 | ||||
Dry
Contact Signals |
UPS
Shutdown, mains failure, low battery, by-pass active, summary
alarm | ||||
ENVIRONMENT |
| ||||
Operating
Temperature |
0
°C ..... +40 °C | ||||
Storage
Temperature |
-15
°C ..... +55 °C | ||||
Proposed
Temp. Extend Battery Life |
20
- 25 °C | ||||
Humidity |
<
95 % | ||||
Audible
Noise at 1m |
<
50dB |
<
55dB | |||
Protection
Class |
IP
20 | ||||
PHYSICAL
SPECIFICATIONS |
|