Model |
GTR1103 |
GTR1105 |
GTR1106 |
GTR1108 |
GTR1110 |
Power
(kVA / kW) |
3kVA
/ 2.7kW |
5kVA
/ 4,5kW |
6kVA
/ 5,4kW |
8kVA
/ 7,2kW |
10kVA
/ 9kW |
Output
Power factor |
0.9 | ||||
Overall
Efficiency (AC-AC) |
94% | ||||
INPUT | |||||
Nominal
Voltage |
220V/230V/240V | ||||
Minimum
Voltage ( at half load ) |
90V | ||||
Minimum
Voltage ( at full load ) |
180V | ||||
Maximum
Voltage |
270V | ||||
Frequency |
45-65
Hz | ||||
Power
Factor |
>0,99 | ||||
Current
Harmonics |
<
6 % | ||||
OUTPUT | |||||
Nominal
Voltage |
220VAC
( factory set & adjustable from LCD panel with 1V steps from 208V to
242V ) | ||||
Voltage
Tolerance |
±1% | ||||
Nominal
current @220V |
13,6A |
23A |
27A |
36,4A |
45,5A |
Wave
Form |
Pure
Sine Wave | ||||
Total
Harmonic Distortion | |||||
at
100% linear load |
<1,5% | ||||
at
100% non-linear load |
<3,5% | ||||
Frequency |
50Hz
or 60Hz (adjustable from LCD Panel) | ||||
Frequency
Tolerance(battery operation) |
0,005
% | ||||
Static
Voltage Regulation (0%-100% load) |
1% | ||||
Dynamic
Voltage Regulation (0%-100% load) |
5% | ||||
Crest
Factor |
3:01 | ||||
Overload |
10
min | ||||
100%
to 125% overload |
1
min | ||||
125%
to 150% overload |
| ||||
Greenmode
( Ecomode ) Efficiency |
>
98% | ||||
BATTERY | |||||
Type |
Maintenance-free
lead acid batteries | ||||
Quantity
(pcs) |
14 |
20 | |||
Recharge
Time |
<
6h - 8 h | ||||
Warning |
Audible
Buzzer through the end of Battery Discharge | ||||
DISPLAY
PANEL | |||||
LCD
Panel |
“Load
%, Input/Output/Bypass Voltages, Output Power ( W & VA ), Output
Current, Output p.f., Battery +/- Voltage
Values, Input / Output Frequency, DC Bus +/-Voltages, Remaining Back Up
Time, Internal Temperature, Heatsink
Temperature” | ||||
Event
Log |
500pcs
( control availability in detail from LCD panel
) | ||||
Audible
and Visual Alarm Warning |
41
different Alarm Messages | ||||
BY-PASS | |||||
Voltage
Tolerance |
±10%
(adjustable) | ||||
Frequency
Tolerance |
3Hz
(adjustable from LCD panel between 0.5Hz to
5Hz) | ||||
Transfer
Time |
0
ms | ||||
Overload
Capability |
up
to 175% | ||||
PROTECTION | |||||
Overload
Protection |
Bypass
transfer time is calculated by simulating a temperature related model of a
fuse | ||||
Short
Circuit Protection |
Acts
as the ideal current source during the short circuit
time | ||||
Other
Protection |
Protection
against excessive heat,voltage,current &
Deep Discharge Protection | ||||
COMMUNICATION | |||||
Interface
(Communication Ports) |
RS232
(standard), SNMP, Modbus and USB (optional) | ||||
Dry
Contact Port ( Option ) |
5pcs
from LCD Panel adjustable dry contact signals | ||||
ENVIRONMENT | |||||
Operating
Temperature |
0
˚C.... + 40 ˚C | ||||
Storage
Temperature |
-15
˚C.....+55 ˚C | ||||
Proposed
Temp. to extend battery life |
20
- 25 ˚C | ||||
Humidity |
<
95% | ||||
Maximum
Altitude |
1000m | ||||
Audible
Noise ( from 1m distance ) |
<50
dB | ||||
Protection
Class |
IP
20 | ||||
PHYSICAL
SPECIFICATIONS | |||||
Net
Weight( without battery ) |
32kg |
33kg |
34kg |
43,5kg |
44kg |
Dimensions(mm)
(WxDxH) |
272mm
x 740mm x 758mm | ||||
STANDARDS | |||||
Standards |
EN
62040-1-1 (safety), EN 62040-2(EMC), EN
62040-3(Performance |