TYPE |
FP1103 |
FP1105 |
FP1106 |
FP1108 |
FP1110 | ||
Power
(kVA) |
3 |
5 |
6 |
8 |
10 | ||
Power
(kW) |
2,4 |
4,5 |
5,4 |
7,2 |
9 | ||
INPUT | |||||||
Phase
Configuration |
1Ph
+ N + PE | ||||||
Nominal
Voltage |
220V/230/240V | ||||||
Minimum
Voltage |
160V |
180V | |||||
Maximum
Voltage |
288V |
280V | |||||
Frequency |
±
5 Hz |
45-65
Hz | |||||
Power
Factor |
0,99 | ||||||
OUTPUT | |||||||
Power
Factor |
0,8 |
0,9 | |||||
Phase
Configuration |
1Ph
+ N + PE | ||||||
Nominal
Voltage |
220V
/ 230 / 240V (adjustable) | ||||||
Wave
Form |
Pure
Sine Wave | ||||||
Total
Harmonic Distortion at 100% linear load |
<3% | ||||||
Frequency |
50Hz
or 60Hz (adjustable) | ||||||
Frequency
Tolerance(free running) |
±0,2
% | ||||||
Static
Voltage Regulation (0%-100% load) |
<1% | ||||||
Crest
Factor |
3:01 | ||||||
Transfer
Time |
0sec | ||||||
Overload |
30sec
@ (%106-%120) |
2min
@ (%100-%120) | |||||
10sec
@ (%120-%150) |
30sec
@ (%120-%150) |
| |||||
Transfer
to bypass @ %150 |
| ||||||
Total
Efficiency* |
≥90% |
≥92% | |||||
BATTERY | |||||||
Type |
Maintenance-free
lead acid batteries | ||||||
Recharge
Time |
4-6h
up to 90% | ||||||
Voltage |
72VDC |
240VDC
( 20 pcs 12V Batteries ) | |||||
(6
pcs 12V Batteries) | |||||||
Cold
Start |
Present | ||||||
DISPLAY | |||||||
LED
+ LCD Display |
Line
Mode, Back up Mode, Eco Mode, Bypass Supply, Battery Low, Battery
Bad/Disconnect, Overload, UPS Fault, Interruption during
transfer | ||||||
LCD
display |
Input
Voltage, Input Frequency, Output Voltage, Output Frequency, Load%, Battery
Voltage, Internal Temperature | ||||||
Self
Diagnostics |
Upon
Power On, Front Panel Setting and Through Software Control, 24h routine
Check | ||||||
PROTECTION | |||||||
Overload
Protection |
Bypass
transfer time is calculated by simulating a temperature related model of a
fuse | ||||||
Short
Circuit Protection |
Acts
as the ideal current source during the short circuit
time | ||||||
Other
Protection |
Against
excessive (heat,voltage,current) intense battery
discharge | ||||||
COMMUNICATION | |||||||
Interface
(Communication ports) |
Standard
RS232 port and optional RS485, Internal SNMP, Dry Contact
Cards | ||||||
ENVIRONMENT | |||||||
Operating
Temperature |
0
˚C.... + 40˚C | ||||||
Proposed
Temp. to extend battery life |
20
- 25 ˚C | ||||||
Humidity |
up
to 90% ( non-condensing ) | ||||||
Audible
Noise at 1 m |
<50
dB | ||||||
PHYSICAL
SPECIFICATIONS | |||||||
Dimensions(mm)
(HxWxD) |
449x226x454 |
585x255x741 | |||||
Weight
- without battery |
19 |
30 |
38 | ||||
STANDARS | |||||||
EMC |
EN62040-2 | ||||||
LVD |
EN62040-1-1 | ||||||
PROTECTION |
IP20 | ||||||
*Global
Efficiency depends on UPS power and environmental
conditions. | |||||||